Quick Details
Place of Origin:
Shandong, China
Brand Name:
Jinheng
Model Number:
XGN15-12
Certificate:
CCC
Supply Ability
Supply Ability:
100 Set/Sets per Month
Packaging & Delivery
Packaging Details
Standard export wooden package
Port
Qindao
Lead Time :
Shipped in 21 days after payment

Fixed HV switchgear, which can be customerized. The price depends on the components which is selected by the customers or depend on the actual requirements.
Rated voltage: 12KV
Frequency: 50Hz
Bus current: 630,1350(A)
Brand: Jinheng

Quick Details

Place of Origin:
Shandong, China (Mainland)
Brand Name:
Jinhengli
Model Number:
12 kV switchgear
Standard:
IEC/GB
CERTIFICATION:
Type test report/CESI/ CTQC/ISO9001
Main voltage range:
35KV/24KV/12KV/0.4KV
Main cabinet type:
KYN28/KYN61/GGD/XGN15/...
Rated capacity:
50,63,80,100,125,200,250,315,400,500,800,1000, 2000,2500A
Frequency:
50Hz or 60Hz
Advantage:
Best price & Best quality in China
CORPORATION::
EEPCO/KPLC/REA/PEC
Customized design:
Available
Product type:
12 kV switchgear

Packaging & Delivery

Packaging Details:12 kV switchgear
1)1 plastic bag/set,1 wooden case/set
2)Special package required by clients.
Delivery Detail:

5-15 days upon receipt of payment

 

 

Product Description

Professional Medium voltage and Low voltage switchgear manufacturer in China

Operating environment: 

1)Ambient temperature:-10°C-+40°C;  

2)Altitude: high voltage ≤1000Meter, low voltage ≤2500Meter (technical department will design specially if exceeds);

3)Relative humidity:≤85%

4)Seismic intensity:≤ magnitude 8;

5Apply to the places have no fire,no explosion danger, no serious pollution,no chemical corrosion and no violent vibration.

  12 kV switchgear

Executive standard:

GB7251         Low voltage complete set switchgear and control device

GB3906-2006    3.6kV~40.5kV AC metal enclosed switchgear and control device

  12 kV switchgear

Technical parameter:

 

35KV high voltage switchgear technical parameter:

12 kV switchgear 

 

Parameter

Rated voltage

kV

40.5~33KV

Rated short time power frequency withstand voltage(1min)(1min)

kV

95

Rated lighting impulse withstand voltage

kV

185

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500

Rated short circuit breaking current

kA

25

31.5

Rated peak value withstand current

kA

63

80

Rated control power

V

AC 110/220,DC 110/220

Dimension

KYN61-40.5

mm

1400*2800*2600

(width* depth* height)

 

 

 

 

 

 24KV high voltage switchgear technical parameter:

12 kV switchgear  

 

Parameter

Rated voltage

kV

24~15KV

Rated short time power frequency withstand voltage(1min)

kV

65

Rated lighting impulse withstand voltage

kV

125

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500

Rated short circuit breaking current

kA

25

31.5

Rated peak value withstand current

kA

63

80

Rated control power

V

AC 110/220,DC 110/220

Dimension

KYN28A-24

mm

1000*1800*2450(width*depth*height)

 

 

 

 

 

 12KV high voltage switchgear technical parameter:

12 kV switchgear  

 

Parameter

Rated voltage

kV

3.6

7.2

12

Rated short time power frequency withstand voltage(1min)

kV

24

32

42

Rated lighting impulse withstand voltage

kV

40

60

75

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500,3150,4000

Rated short circuit breaking current

kA

20

25

31.5

40

50

Rated peak value withstand current

kA

50

63

80

100

125

Rated control power

V

AC 110/220,DC 110/220

Dimension

(width*depth*height)

KYN28A-12

mm

(800/1000)*1500*2300

XGN2-12

mm

1100*1200*2650

HXGN-12

mm

(375/500)*900*1850

 

 

 

 

 

 

 

 

 

 

 0.4KV low voltage switchgear technical parameter:

 

 

Parameter

Rated voltage

V

               400

690

Rated insulation voltage

V

690

1140

Rated impact withstand voltage

V

6000

10000

Rated working short circuit breaking ability

kA

18~100

10~75

Rated utmost short circuit breaking ability

kA

25~120

20~85

Rated frequency

Hz

50/60

Rated current

A

400,500,630,800,1000,1250,1600,2000,2500,3150,4000,5000,6300

Rated control power

V

AC 110/220/380,DC 110/220

Dimension

(Unit:mm)

MNS/GCS/GGD

width

400,600,800,1000,1200

depth

600,800,1000

height

2200